Automatic gel imaging analysis system ZF-268
0512-67158275hsy_001@hsy515.cn
  1. Share:

Brief introduction:


Automatic gel imaging analysis system ZF-268:CCD photosensitive chip, Microvision chip, automatic gel imaging analysis system ZF-268 camera: beautiful Microvision resolution low illumination digital camera, detection signal-to-noise ratio of more than 56dB, effective pixel: 2048 (H) x1536 (V), resolution: 3 million pixels, collection bits: moving lens, Computar 8 ~ 48mm, aperture: automatic F1:1.2, exposure time: 1ms-2s. Dynamic range: > 3.6 quantitative detection sensitivity: lower than 20pg EB stained dsDNA.



Details:


Independently developed and produced automatic gel imaging analysis system ZF-268 adopts hardware and software configuration of scientific and technological means: resolution, quality and clarity CCD camera, automatic computer control, degree programming, digital camera can realize imaging and imaging control by connecting with computer. The analysis software can realize image editing, automatic lane recognition, molecular weight calculation and sample size. Cloth calculation, etc. To ensure the sensitivity, loss and stripe of images of DNA/RNA gel, protein gel, imprinted hybrid membrane (including Western, Southern, Northern, Slot/ dot blotting), autoradiographic film, enzyme labelling, thin-layer chromatography, chemical fluorescence and other images, the peak value, molecular weight or base logarithm, area, degree, location, volume or shape of the gel strip can be obtained. Total amount of products. EB pollution should be controlled to a large extent to ensure the health of experimental operators. It is helpful to get electrophoretic photos and analysis results correctly and quickly, get rid of tedious operation process and improve work efficiency.



The automatic gel imaging analysis system ZF-268 can be used for image processing and analysis of DNA/RNA gel, protein gel, imprinted hybrid membrane (including Western, Southern, Northern, Solt, dot hybridization membrane), autoradiographic film, enzyme labeled board and thin layer chromatography plate. It can carry out gross analysis, molecular weight analysis and cluster analysis for strips, spots and any other target areas. And homology analysis.




The main application area of the automatic gel imaging analysis system ZF-268 is:


Nucleic acid detection: DNA / RNA detection with various fluorescent dyes, such as ethidium bromide, sybrtmgold, sybrtmgreen, sybrtmsafe, gelstartm, fluorescein, Texas Red. Protein detection: Coomassie brilliant blue glue, silver burning glue, and fluorescent dyes such as syprot red, syprot orange, Pro-Q diamond, deep purple label glue / film / chip, etc. Other applications: all kinds of hybrid membrane, protein transfer film, plate colony count, enzyme plate, TLC plate, etc.




The function of automatic gel imaging analysis system ZF-268 is:


Multi function control panel, touch button, function selection is simple and convenient


The zoom, focus, aperture, transmission UV lamp and reflector can be controlled automatically by software or chassis panel;


The clarity and quality images of scientific research CCD reflect more details of the picture, and the ability to analyze weak bands is stronger


Through the software or anti ultraviolet (UV) observation window, the sample can be observed in real time, which is more intuitive;


Timing protection function: no command is input within 10 minutes, all light sources are automatically turned off, and the service life is prolonged


Turn off the operation software: the system automatically turns off all light sources at the same time,


The sealed darkbox is designed for chemiluminescence and bioluminescence


Unique design of double door tapping window on both sides: users can cut glue directly in the dark box to effectively prevent EB pollution


Drawer type lamp box with double fan cooling system can automatically cut off the ultraviolet light source when the drawer is opened to avoid ultraviolet damage


Image function: adjust image size, brightness, gray level, contrast, angle, strip calibration, reverse color, cutting, rotation, scaling, adding text


Analysis software and image acquisition software were implemented in the same interface: image capture, electrophoresis gel electrophoresis, dot blot, narrow line imprinting and colony counting.


The levelness and perpendicularity of strip can be adjusted: the levelness and perpendicularity of strip can be adjusted manually to obtain more accurate data.


Technical indexes and parameters: No.: 2008 3 0130298.3


Automatic gel imaging analysis system ZF-268


CCD sensitive chip micro vision chip


Camera: micro vision resolution low illumination digital camera


Detection signal to noise ratio ≥ 56dB


Effective pixel: 2048 (H) x1536 (V)


Resolution: 3 megapixels


Acquisition bits: moving lens, Computar 8-48mm


Aperture: f1:1.2 automatic


Exposure time: 1ms-2s


Dynamic range: > 3.6 quantitative detection sensitivity: lower than 20pg EB stained dsDNA


Lighting mode: transmission ultraviolet, transmission white light, reflected white light (blue light transmission is optional)


Excitation light source transmission: 300nm, white light, (optional transmission blue light 200 x120mm)


Double side reflection white light lamp (cold light) (R type: 254nm, 365nm, UV reflection 200 × 50mm)


Filter: Standard 590nm, compatible with EB, SYBR, Goldview and other fluorescent dyes


Shooting area: UV: 200 × 250mm, white light: 210 × 260mm


Tapping observation device: observation window 60 × 125mm, tapping window 100 × 125mm


Software: the United States imported gel analysis software (Chinese and English version) JP-GEL 1D image analysis software (optional 2D analysis software)


Installation: free installation and debugging training


Configuration: professional glue cutting tools are included


Interface USB2.0, image can be directly stored and printed, XP / win7 system is compatible.