- -86 ℃ sample management ultra-low temperature storage box
- -86 ℃ ultra-low temperature box
- -60 ℃ frequency conversion ultra-low temperature storage box
- -40 ℃ low temperature storage box
- -25 ℃ low temperature storage box
- Medical refrigerated freezer
- 2-8 ℃ medical refrigerator
- 4 ℃ blood refrigerator
- 20-55 ℃ heating storage box
- -150 ℃ deep and low temperature storage box
- Portable medical refrigerator
- Chromatography cabinet
Centrifuge
Your current location:Home / Product / Laboratory equipment / Mixed separation / Centrifuge- CTK150 automatic decapping centrifuge
- 0512-67158275hsy_001@hsy515.cn
-
Product introduction
At present, when collecting blood samples in hospitals at all levels, vacuum blood collection is widely used. After blood centrifugation, the cap must be removed manually, which is inefficient. The vibration produced during cap removal may lead to blood re mixing and increase the risk of bacterial infection. The ctk150 automatic decapper centrifuge developed by Xiangyi has a remarkable effect, which completely solves the problem of decapper of vacuum blood collection vessels in hospitals at all levels, and is an ideal test instrument for hospitals at all levels.
Instrument features
◆ automatic decapitation of evacuated blood vessels, the success rate of decapitation is more than 90%
◆ applicable to two lengths of 100mm and 75mm
◆ touch panel, large screen LCD, easy to operate
◆ adopt AC variable frequency motor, high speed control accuracy, with fast speed up and speed down function
◆ automatic calculation of RCF value
◆ special shock absorber is adopted, with good shock absorption effect and automatic balance function
◆ adopt electronic door lock, with strong safety performance. If the door cover is not closed properly, the centrifuge cannot be started; if the door cover is opened abnormally during operation, it will stop automatically
◆ abnormal opening and automatic shutdown
TECHNICAL PARAMETER
model | CTK150 |
Order No | 0205255009 |
Maximum speed | 4000r/min |
Maximum relative centrifugal force | 3850×g |
Maximum number of centrifugal tubes | 150(ɸ13×75/100mm) |
Speed accuracy | ±30r/min |
Timing range | 1sec~99min59sec |
Noise of the whole machine | ≤65dB(A) |
Power Supply | AC220V ±22V 50Hz 10A |
Overall power | 2000W |
Boundary dimension | 700×880×930mm(L×W×H) |
Package size | 820×100×1080mm(L×W×H) |
weight | 220kg |
CTK150 automatic decapping centrifuge rotor
model | Product name | Maximum speed(r/min) | Maximum relative centrifugal force (×g) | Maximum number of centrifugal tubes |
No.1 | Horizontal rotor body | 4000 | 3850 | 150(ɸ13×75/100mm) |
hanging basket | 4000 | 3850 | ||
Adapter | 4000 | 3850 | Adapter 75mm | |
Adapter | 4000 | 3850 | Adapter 100mm |